Home> Blog> No More Leaks: The Ultimate Pump Flange Fix

No More Leaks: The Ultimate Pump Flange Fix

September 25, 2026

Stop costly leaks and unexpected equipment downtime with the ultimate Pump flange fix. Engineered for a secure, dependable seal, this durable solution helps prevent fluid loss, withstand demanding operating conditions, and maintain consistent pump performance. Its reliable fit simplifies maintenance, reduces the risk of recurring flange problems, and supports longer service intervals. Protect your equipment, improve efficiency, and extend pump service life with a sealing solution built for lasting results.



Stop Pump Flange Leaks for Good


A pump flange leak can start as a few drops around the joint. Left unchecked, it may lead to pressure loss, corrosion, damaged equipment, slippery floors, or unplanned maintenance. Replacing the gasket alone often does not solve the problem when the flange faces, bolts, pipe alignment, or operating conditions are also part of the issue.

When I troubleshoot a leaking pump flange, I look at the full connection instead of focusing on the visible drip.

Start with a safe inspection

I shut down the pump according to the site procedure, isolate the line, release stored pressure, and allow hot fluid to cool. I also use the required protective equipment for the fluid being handled.

A leaking flange should not be tightened while the pump is running unless the equipment maker and site procedure specifically allow it. A pressurized joint can release fluid without warning, and tightening one bolt may shift the load across the flange.

I check the leak location before removing anything:

  • Is fluid coming from the gasket line?
  • Is it leaking around a bolt?
  • Is the flange cracked?
  • Is the pipe moving when the pump starts?
  • Does the leak appear only when the system reaches operating temperature?

The answer helps separate a gasket problem from a wider installation problem.

Check pipe alignment and support

Misaligned piping places force on the pump flange. The pipe may look close to the correct position, yet the bolts may be pulling it into place. This can distort the flange and create an uneven gasket load.

I look for:

  • Pipe sections that do not line up naturally
  • Excessive force needed to insert the bolts
  • Missing or loose pipe supports
  • Heavy valves hanging from the pump connection
  • Movement during startup or shutdown
  • Vibration transferred from nearby equipment

A practical test is to loosen the flange bolts after the system has been isolated and supported safely. If the pipe springs away from the pump, the connection has external stress. The piping should be corrected before a new gasket is installed.

A gasket cannot compensate for a pipe that is constantly pulling on the pump flange.

Inspect the flange faces

Once the joint is open, I clean both flange faces and inspect them under good lighting. Old gasket material, rust, paint, scratches, and dents can create leak paths.

Look for:

  • Deep radial scratches
  • Pitting around the sealing area
  • Warped or bent flange faces
  • Raised areas near bolt holes
  • Weld spatter or hard deposits
  • A damaged gasket seating surface

Light surface marks may be manageable, depending on the flange design and gasket type. Deep damage may need repair or replacement. I do not use excessive sealant to cover a damaged face. That approach can create a short-term seal while making later maintenance harder.

The flange surface must match the gasket and service conditions. A gasket designed for a raised-face flange may not perform correctly on a different face style.

Select the correct gasket

The gasket should match the fluid, temperature, pressure, flange material, and surface finish. I confirm the gasket material against the pump manual, piping specification, or approved maintenance standard.

Common gasket failures come from:

  • Choosing a material that is not compatible with the fluid
  • Using the wrong thickness
  • Installing a gasket that is too small or too large
  • Reusing a compressed gasket
  • Installing a gasket with folds or damage
  • Using sealant where the gasket maker does not permit it

For a water service, the correct gasket may differ from one used with oil, chemicals, steam, or abrasive slurry. A gasket that works well on one pump may fail on another service.

I keep the gasket dry and clean unless the manufacturer gives different instructions. I place it carefully so it stays centered during assembly.

Check the bolts and nuts

A flange joint depends on even compression. Dirty, damaged, stretched, or corroded bolts can produce uneven load even when the wrench reaches the expected torque.

I inspect:

  • Bolt threads
  • Nut condition
  • Washers
  • Corrosion
  • Thread lubricant
  • Bolt length
  • Signs of previous over-tightening

The specified torque depends on bolt size, material, gasket type, lubrication, and flange design. A torque value from another connection should not be copied without checking the equipment requirements.

Dry threads and lubricated threads do not produce the same clamping force at the same torque. I use the approved lubricant and torque information for the joint.

Tighten in a cross pattern

After the flange is aligned and the gasket is centered, I install the bolts by hand. I bring the joint together gradually with a cross-pattern sequence rather than tightening one side at a time.

A typical sequence may use:

  • A light pass to seat the gasket
  • A middle pass to build even compression
  • A final pass at the specified torque
  • A check around the joint after all bolts reach the target

The exact sequence and torque should follow the flange and gasket requirements. Large flanges may need more passes.

I mark the bolts after the final check when the site uses visual torque control. This helps identify movement during later inspections, though a mark does not replace a proper torque check.

Reduce vibration and movement

A pump flange may leak again if vibration remains. I inspect the pump base, coupling, bearings, motor alignment, and nearby pipe supports.

A simple example is a centrifugal pump that leaks only during startup. The joint may remain dry while the pump is stopped, then open slightly when vibration and pipe movement increase. Replacing the gasket without checking the base, coupling, or support system may produce the same leak weeks later.

I compare the leak pattern with operating conditions:

  • Leak only at startup: check movement and alignment
  • Leak after heating: check thermal expansion and gasket selection
  • Leak at higher pressure: check joint load and flange condition
  • Leak near one bolt: check local damage or uneven compression
  • Leak after maintenance: review assembly method and torque control

This pattern often gives more useful information than the size of the drip.

Test the repaired joint

After assembly, I restore the system slowly and inspect the joint during a controlled pressure test. I look for moisture, seepage, vibration, and movement around the flange.

The test pressure and method should follow the equipment and site procedure. I do not stand directly in front of the flange during pressurization. If the joint remains dry at low pressure, I continue checking as the system reaches its normal operating range.

A dry flange during a cold test does not always prove that the repair will hold when the fluid becomes hot. Thermal expansion can change the load on the connection.

Keep a clear maintenance record

I record the gasket material, bolt condition, torque method, operating pressure, fluid temperature, and observed leak location. Photos of the flange faces can also help when the same connection has repeated problems.

Repeated leaks often point to a design or installation issue. The maintenance record makes that pattern easier to see. It can show that the same pump leaks after every shutdown, only during winter operation, or whenever a nearby valve is opened.

My approach is simple: make the joint clean, aligned, correctly compressed, and free from avoidable movement. A new gasket is only one part of the repair. When the flange faces, piping, bolts, gasket, and operating conditions are checked together, the chance of another pump flange leak becomes much lower.


The Ultimate Pump Flange Fix You Can Trust



A leaking pump flange can look like a small maintenance issue, yet a loose bolt, damaged gasket, or poor pipe alignment may lead to vibration, fluid loss, and repeated shutdowns. I do not treat every leak with the same fix. The right repair depends on the fluid, pressure, flange type, gasket condition, and pipe load around the pump.

A sound repair starts with finding the real cause.

Check the area before opening the flange

I begin by checking the leak pattern.

A leak at one point around the flange may suggest uneven bolt load or a damaged gasket. A leak around the full joint can point to poor alignment, a warped flange face, or the wrong gasket size. Rust marks and wet trails may show that the joint has been leaking for some time.

I also check for:

  • Pump vibration
  • Loose or missing bolts
  • Pipe strain
  • Corrosion around the flange face
  • Scratches or dents on the sealing surface
  • Signs of pressure or temperature stress

The fluid matters as well. Water, oil, steam, chemicals, and slurry need different gasket materials and handling methods. A gasket that works on a clean water line may not suit a hot oil system.

Make the system safe

Before loosening any flange bolts, I isolate the pump and connected lines. The system should be depressurized, drained, and cooled to a safe temperature. Lockout and tagout procedures help prevent an unexpected start.

For chemical, steam, or contaminated lines, I use the site’s required protective equipment and cleaning process. A flange should never be opened just because the visible leak looks small.

Remove the old gasket

I loosen the bolts in a controlled pattern. If the joint still holds pressure, the bolts may release stored force when loosened. I keep my body away from the direct line of the joint while checking that the system is empty.

After removing the old gasket, I inspect it for clues:

  • A crushed section may show uneven bolt pressure
  • A split edge may point to movement or pipe strain
  • Burn marks may suggest excessive heat
  • Chemical softening may show poor material selection
  • A gasket pushed into the pipe bore may indicate the wrong size

I remove old gasket material without gouging the flange face. Deep scratches can create a leak path even when the new gasket appears to fit.

Inspect the flange and pipe alignment

A clean flange face is not enough. Both flange faces need to sit in the same line without force from the pipe.

If I have to pull the pipe into position with the bolts, the joint is under stress. That stress can return as soon as the pump starts. It may also damage the pump casing or coupling.

I check:

  • Flange face condition
  • Bolt-hole alignment
  • Pipe support
  • Pipe movement near the pump
  • Pump and motor alignment
  • Signs of a warped or tilted flange

A straightedge, feeler gauge, or flange alignment tool can help identify gaps. The exact limits should come from the pump and flange manufacturer.

Choose the correct gasket

The replacement gasket must match the flange rating, size, face type, pressure, temperature, and fluid.

Common options include:

  • Compressed fiber for selected water and utility services
  • PTFE for many chemical applications
  • Spiral-wound gaskets for suitable high-temperature or high-pressure systems
  • Rubber-based gaskets for compatible low-pressure services

I use the gasket specification rather than choosing by appearance. The inner diameter should not block the flow path, and the outer diameter should sit correctly inside the bolt circle.

A gasket should be installed dry unless the manufacturer gives another instruction. Adding sealant to a gasket can change its compression and may make future removal harder. Sealant also cannot correct a damaged flange face.

Install and tighten the bolts evenly

I place the gasket without folding, stretching, or pushing it into the pipe. The flange faces should meet in a parallel position.

The bolts should be clean and suitable for the flange assembly. Damaged threads, heavy corrosion, or mixed bolt grades can affect the clamping force.

I tighten the bolts in a cross pattern:

  1. Bring the bolts into light contact by hand.
  2. Tighten them in a diagonal sequence.
  3. Increase the torque in several passes.
  4. Use the torque value specified for the bolt, flange, gasket, and service.
  5. Make a final pass around the flange in the required sequence.

Torque values are not universal. Lubricated threads can produce more clamping force than dry threads at the same torque reading, so the chosen value must match the site procedure or equipment guidance.

Test the repair

After the flange has been assembled, I inspect the joint before starting the pump. I check that the pipe is supported, the pump shaft turns as expected, and no tools or loose materials remain near the equipment.

The test method depends on the service. A water pressure test may suit one system, while another may require a controlled operating test or a leak detection process. I raise pressure gradually and watch the flange, nearby joints, pump seals, and gauges.

A dry flange during the initial test does not always prove that the repair will remain sound. I check it again after the pump reaches normal temperature and operating pressure.

A common field example

A wastewater pump may develop a small leak at its discharge flange after a gasket replacement. The gasket itself may not be the main problem.

During inspection, a technician may find that the pipe support has settled. The discharge pipe then pulls the flange slightly out of line. The bolts hold the joint together, but the pressure is uneven across the gasket. When the pump vibrates, the weak section begins to leak.

Replacing the gasket alone may provide a short-term result. Restoring the pipe support, correcting the alignment, checking the flange faces, and tightening the bolts with the specified pattern address the conditions that caused the leak.

When a flange needs replacement

A new gasket is not enough when the flange face is badly pitted, cracked, warped, or worn below its service limits. A damaged raised face may need machining or replacement. A cracked pump casing or corroded pipe spool requires a repair plan suited to the equipment and fluid.

I also avoid repeated bolt tightening as a routine fix. More torque can damage the gasket, distort the flange, or overload the pump connection. If a joint keeps leaking, I look for alignment, vibration, material, pressure, and surface problems.

A reliable pump flange repair is built on inspection, safe isolation, correct gasket selection, even bolt loading, and a controlled test. When I treat the leak as a symptom rather than the whole problem, the repair has a better chance of lasting through normal pump operation.


Keep Your Pump Tight, Dry, and Leak-Free



A pump that stays tight and dry is easier to inspect, easier to maintain, and less likely to interrupt daily work. Small leaks often begin with a loose fitting, a worn seal, excess vibration, or water left around the base. I prefer to treat these signs as maintenance clues rather than waiting for a larger problem.

A dry pump area also helps me spot changes early. When the floor, drip tray, or casing remains clean, a new drop of fluid becomes much easier to notice.

Start with a safe inspection

Before I touch the pump, I shut off the power and release pressure from the system. I also follow the instructions supplied with the pump. A hot surface, moving part, or pressurized line can cause injury.

I check:

  • The pump body
  • Suction and discharge connections
  • Pipe joints
  • Mechanical seal area
  • Drain plugs
  • Gaskets and O-rings
  • Mounting bolts
  • The floor beneath the pump

A flashlight helps me see small wet spots. A clean piece of cardboard placed under the pump can also show the location and color of a leak.

Clear water may point to a plumbing connection or condensation. Dark fluid, oily marks, or fluid with an unusual smell may come from the pump or motor area. I avoid guessing when the fluid type is unclear. I check the equipment guide or ask a qualified technician.

Check the connections without over-tightening

Loose fittings are a common source of leaks. I inspect threaded joints, flexible connectors, flanges, and hose clamps.

I look for:

  • A fitting that moves by hand
  • Cracked thread seal tape
  • Flattened or damaged gaskets
  • A hose that has hardened near the clamp
  • Rust around a flange
  • Marks showing that a joint has been shifting

I tighten fasteners evenly and use the torque range provided by the manufacturer. Too little force may leave a gap. Too much force can damage a gasket, crack a fitting, or distort the pump casing.

When a connection continues to leak after careful tightening, I stop adding force. I remove the pressure, inspect the sealing surface, and replace the damaged part if needed.

Give seals and gaskets a closer look

The seal area often needs more attention than the outside of the pump suggests. A mechanical seal may show a light film during normal operation, depending on the pump design. A steady drip, wet trail, or fluid collecting below the shaft area deserves inspection.

I look for:

  • Moisture near the shaft
  • Drops appearing while the pump runs
  • A worn O-ring
  • A gasket that has become hard or cracked
  • Scratches on a sealing surface
  • A shaft that shows wear near the seal

I replace seals and gaskets with parts that match the pump model and fluid service. A part that looks similar may have a different size, material, or temperature rating.

I also keep sealing surfaces clean. Dirt caught between two surfaces can create a leak even when the fasteners are tight.

Watch vibration and pipe strain

A pump can stay dry for a while and still be under stress. Misaligned pipes, weak supports, or an unbalanced rotating part may place force on the casing and connections.

I pay attention to:

  • New vibration
  • Rattling sounds
  • A change in motor noise
  • Pipe movement during startup
  • Loose base bolts
  • A pump that shifts on its mount
  • Uneven support beneath the piping

A pump should not carry the weight of unsupported pipework. I check that nearby pipes have suitable support and that the pump connections are not being pulled sideways.

A simple example is a small water transfer pump mounted beside a storage tank. If the discharge pipe sags, its weight can pull on the outlet connection. The joint may begin with a small wet mark and later leak when the pump starts and stops. Supporting the pipe can remove that strain and protect the connection.

Keep moisture away from the motor

Not every wet spot comes from the pump chamber. Condensation, splashing, and poor drainage can allow water to reach the motor or electrical box.

I check:

  • Cable entry points
  • Terminal covers
  • Drain holes
  • Ventilation openings
  • The direction of nearby spray
  • Water collecting on the base
  • Signs of rust around electrical parts

I do not spray the motor or electrical enclosure during cleaning. I wipe the outside with a suitable cloth and keep the area ventilated. If water has entered an electrical section, I leave the power off and arrange a qualified inspection.

A small roof leak above a pump room can create repeated moisture that looks like a pump problem. Finding the source saves time and prevents damage to both the pump and motor.

Use a simple leak-check routine

I use the same routine each time so small changes are easier to compare.

  1. Clean the outside of the pump and nearby pipe joints.
  2. Dry the base, fittings, and seal area.
  3. Mark the fluid level in a drip tray if one is fitted.
  4. Start the system according to the operating instructions.
  5. Watch the pump during startup and normal operation.
  6. Check the area again after shutdown.
  7. Record the location, amount, and timing of any fluid.

The timing can help narrow the cause. A leak that appears only during startup may relate to pressure movement or vibration. A leak that continues after shutdown may come from a tank head, damaged check valve, or a joint that remains under pressure.

I avoid placing my hands near a running shaft or coupling. A piece of cardboard or a dry inspection cloth can help reveal spray without putting fingers near moving parts.

Keep the pump dry through routine care

A clean maintenance area supports better inspection. I remove standing water, keep the base accessible, and avoid storing boxes against the pump. Clutter can hide a leak until the fluid reaches another part of the room.

My regular checks include:

  • Looking for fresh drops
  • Checking the condition of hoses
  • Inspecting clamps and flanges
  • Listening for changes in sound
  • Checking unusual vibration
  • Confirming that supports remain firm
  • Reviewing motor and pump temperature
  • Cleaning blocked drainage paths

The right inspection interval depends on the pump, fluid, operating hours, and environment. A pump moving clean water in a dry room may need a different schedule from a pump working with dirty fluid, heat, or outdoor exposure.

Know when to stop the pump

I stop operation when the leak is growing, the motor area becomes wet, the pump shows strong vibration, the fluid is hot or hazardous, or the pressure cannot be controlled safely.

I also stop when a repair requires opening a sealed section that I cannot service correctly. Replacing a gasket may be a simple task on one pump and a specialist repair on another. The manual, pump design, and fluid type should guide that decision.

A dry floor does not prove that every part of a pump is healthy. It does show that inspection is easier and that visible leakage has not been ignored. My approach is simple: isolate the equipment, find the source, correct the cause, and watch the pump after the repair. A tight connection helps, but stable support, sound seals, clean drainage, and regular checks help keep the whole system dry.


Say Goodbye to Costly Pump Flange Leaks



A leaking pump flange can start as a small wet mark and grow into a costly maintenance problem. Liquid loss, damaged insulation, corrosion, unplanned shutdowns, and cleanup work can all follow. I have found that the leak itself is often only the visible part of the issue. The real cause may be poor alignment, the wrong gasket, uneven bolt load, or pipe stress.

A reliable repair begins with inspection rather than simply tightening the bolts.

Check the leak before removing anything

I start by identifying the liquid, temperature, pressure, and leak location. A water leak needs a different approach from an oil, chemical, or hot-fluid leak.

I also check whether the liquid is:

  • Coming from the gasket face
  • Moving along a bolt or washer
  • Escaping from a crack
  • Running down from a nearby seal or pipe joint
  • Appearing only when the pump is running

This step prevents a common mistake: repairing the flange when the actual leak is coming from the mechanical seal, casing, or pipe connection above it.

The pump should be isolated, depressurized, drained, and allowed to reach a safe temperature before work begins. Site procedures and equipment instructions should guide the shutdown process.

Look for the main causes

Several conditions can create repeated flange leaks.

Uneven bolt loading

When one bolt is tightened much more than the others, the flange may tilt. One part of the gasket receives too much pressure while another part receives too little.

I prefer a cross-pattern tightening method. I bring the bolts into contact, apply torque in several passes, and move across the flange rather than working around it in a circle. A calibrated torque wrench helps keep the load more consistent.

The correct torque depends on the bolt size, material, gasket type, lubrication, and flange design. A torque value from a different connection may cause damage, so I check the equipment manual or the gasket supplier’s guidance.

Flange misalignment

Pipework should meet the pump without force. If I need a lever, pry bar, or heavy pull to line up the holes, the pipe may be placing stress on the pump flange.

That stress can return after the bolts are tightened. The result may be a leak that appears again after startup or after the system reaches operating temperature.

A basic alignment check includes:

  • Matching bolt holes without forcing
  • Checking the flange faces for parallel position
  • Looking for pipe movement when the pump bolts are loosened
  • Supporting nearby pipework with suitable supports
  • Checking that the pump base and coupling remain aligned

Pipe supports should carry the pipe load. The pump flange should not act as a support point.

Gasket selection

A gasket that works well on cold water may not suit hot oil, steam, solvents, or abrasive slurry. I check the fluid, pressure, temperature, flange surface, and gasket material before selecting a replacement.

The new gasket should match the flange size and bolt pattern. It should be clean, flat, and free from tears, folds, oil, or dirt. Many flange connections are designed for one gasket only. Adding a second gasket can change the load pattern and create another leak path.

Flange face condition

Scratches, dents, rust, old gasket material, and raised marks can stop the new gasket from sealing. I clean the faces with a method that does not damage the sealing surface.

A deep groove may need repair or replacement. A quick layer of sealant can hide the problem for a short period, yet it may not provide a stable repair. Sealant should only be used when the equipment or gasket instructions allow it.

A practical repair process

I use this sequence for a standard pump flange inspection:

  1. Isolate and depressurize the pump.

  2. Confirm that the connection is safe to open.

  3. Remove the old bolts and gasket.

  4. Clean both flange faces.

  5. Inspect the faces, bolts, nuts, washers, and nearby pipework.

  6. Check flange alignment without forcing the connection together.

  7. Install the correct gasket in the correct position.

  8. Fit clean, suitable bolts and washers.

  9. Tighten the bolts by hand.

  10. Apply torque in a cross pattern over several passes.

  11. Reconnect the system and check for leaks during a controlled startup.

  12. Record the gasket type, torque method, operating conditions, and inspection result.

The record helps me spot patterns. If the same pump leaks after every maintenance cycle, replacing the gasket again may not solve the problem. Pipe strain, vibration, flange damage, or pump movement may need attention.

A maintenance example

A small water-treatment facility had a recurring leak at the discharge flange of a centrifugal pump. The team replaced the gasket several times. The leak returned after the pump ran for several hours.

During inspection, the pipe was found to be slightly out of line. The flange bolts were pulling the pipe toward the pump. The team adjusted the pipe support, corrected the alignment, cleaned the flange faces, and installed a suitable gasket. The bolts were tightened in controlled stages with a torque wrench.

The repair lasted longer because the team addressed the load on the connection instead of treating the gasket as the only problem.

How to reduce repeat leaks

I focus on a few routine actions:

  • Inspect pump and pipe alignment after major pipework changes.
  • Check for vibration during operation.
  • Replace damaged bolts instead of reusing them without inspection.
  • Keep gasket records for each service line.
  • Use a planned torque method.
  • Check pipe supports during pump maintenance.
  • Inspect for corrosion around the flange and fasteners.
  • Review the leak history before selecting another gasket.

A flange connection should seal through correct fit, suitable materials, and even bolt loading. Tightening harder is not a repair plan. It can distort the flange, damage the gasket, or stretch the bolts.

When I treat the leak as a system issue rather than a single loose bolt, the repair becomes easier to verify and less likely to return. The goal is not to hide a wet spot for a short period. It is to restore a sound connection that matches the pump, pipework, fluid, and operating conditions.

We welcome your inquiries: baobing728@163.com/WhatsApp +8613914457919.


References


American Society of Mechanical Engineers, 2022, ASME B16.5 Pipe Flanges and Flanged Fittings

International Organization for Standardization, 2017, ISO 7005-1 Metallic Flanges

Fluid Sealing Association, 2021, Gasket Installation Procedures for Reliable Flange Sealing

John Bickford, 2008, An Introduction to the Design and Behavior of Bolted Joints

Robert W Budynas and J Keith Nisbett, 2020, Shigley’s Mechanical Engineering Design

Hydraulic Institute, 2022, Rotodynamic Pumps Guideline for Installation Operation and Maintenance

Contact Us

Author:

Mr. Zeng

Phone/WhatsApp:

+86 13914457919

Popular Products
You may also like
Related Information
Is Your Current Flange Costing You Money Daily?

Is your current flange quietly increasing operational costs through leaks, unexpected downtime, frequent repairs, and premature replacement? A high-quality, precision-engineered flange can provide

The Shocking Truth About Automotive Pump Flange Failures

Automotive Pump flange failures rarely ha

Don’t Let Bad Seals Ruin Your Rail Accessories Game

Don’t let faulty seals undermine the performance of your

5 Reasons Your Transport Fleet Needs Better Flanges

Upgrading your transport fleet with high-quality flanges is a practical investment in safety, reliability, and efficiency. Better flanges create stronger, more secure connections, helping prevent l

Related Categories

Email to this supplier

Subject:
Email:
Message:

Your message must be between 20-8000 characters

Contact Us

Author:

Mr. Zeng

Phone/WhatsApp:

+86 13914457919

Popular Products
Contact Us
Subscribe
Follow Us

Copyright © 2026 Chuzhou Yuehe Machinery Manufacturing Technology Co., Ltd. All rights reserved. Privacy Policy

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Send